russian version

 

Portable X-ray diffractometer "Boule"

PORTABLE X-RAY DIFFRACTOMETER FOR SHEAR- CUT ORIENTATION ANALYSIS IN SINGLE- CRYSTAL BOULE

(based on capillary optics)

  •         miniature

  •         easy alignment and sample change

  •         radiation safety

  •         high accuracy of deviation angle determination

  •         express method

  •         permits in-line application       

 

 

Intended use of x-ray diffractometer "Boule": designed for quick determination of orientation of the first cut in large grown single crystals of Si, corundum, quartz, based on deviation of diffraction maximums, wherein the convergent primary x-ray beam had an axis perpendicular to the surface of single-crystal boule cut

 

 

Principle of operation the x-ray diffractometer "Boule":   Kumakhov polycapillary lens (capillary optics, X-ray optics) used to form a convergent beam with convergence angles of ~ 5° permits to receive diffraction reflexes immediately from several crystallographic planes, forget use of complicated goniometer devices to rotate the sample, considerably reduce their exposure time (down to several seconds).

 

Software of x-ray diffractometer

Software permits simultaneous processing of input from two detectors to determine orientation of the diffraction cone. 

Goniometer Device of the x-ray diffractometer "Boule"  On the goniometer device, an x-ray tube equipped with a polycapillary lens forming a convergent x-ray beam is mounted. To register the picture of diffraction, two linear-coordinate detectors are placed at equal angular distances from the x-ray tube. The goniometer is put on top of a support, which axis is parallel to the axis of boule. When specified crystallographic plane coincides with the cut surface plane, detectors register two symmetric peaks; when they do not coincide – the two peaks will be asymmetric.

Electronic Control Unit   Electronic control unit of x-ray diffractometer "Boule" includes high-voltage power supplies to x-ray tube and linear-coordinate detector, ADC, input matching board, and power supply control unit.

 

 

Basic Characteristics of X-ray Diffractometer "Boule"

Error of measurement of angular positions of single crystal diffraction maximums, degrees

Not more than 0.015

Mean square deviation of measuring angular positions of single crystal diffraction maximums, degrees.

 

  0.025

Range of 2q diffraction angles, degrees. 

from 20 to 80

Power consumption, not more, VA

250

Line voltage, V

Frequency, Hz

220±22

50 - 60

Weight, not more, kg

 25

Dimensions, not more (length õ width õ height), mm

 - goniometer device

 - power supply & registration unit

 

 

 300 õ 450 õ 450

   500 õ 260 õ 400

 

CONSISTS FROM:

1. Goniometer Device

2. Electronic Control Unit   3. Portable computer

 

Articles                     Books and patents                   X- ray optical systems                  X-ray devices               Awards       

  Production          New developments          Exhibitions and Conferences              Museum of IRO           Contacts


>>New developments

 

>>Five generations of X-ray lenses
 

 

1-st generation

 

2-nd generation

 

3-d generation

 

4-th generation

 

5-th generation

 

 

Diploma SPIE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-ray devices

 

 X- ray optical systems

 

 New developments

 

 

 

Production

 

 

 

   Capillary optics

Institute for Roentgen Optics: X-ray optics, Neutron optics, Kumakhov optics  +7 499 151 49 56

Nanotechnology